Elementos |
![]() 433999-0143 Tipo NWC Conducto para cableado nuclear Conducto de metal flexible a prueba de líquidos (LFMC) |
![]() 434009-0143 Tipo NWC Conducto para cableado nuclear Conducto de metal flexible a prueba de líquidos (LFMC) |
![]() 434019-0143 Tipo NWC Conducto para cableado nuclear Conducto de metal flexible a prueba de líquidos (LFMC) |
![]() 434029-0143 Tipo NWC Conducto para cableado nuclear Conducto de metal flexible a prueba de líquidos (LFMC) |
![]() 434039-0143 Tipo NWC Conducto para cableado nuclear Conducto de metal flexible a prueba de líquidos (LFMC) |
|||||
Descripción |
N/A
Chlorinated polyethylene jacket with bonding wire through 1-1/4" Conduit shall be Anaconda SEALTITE® Type NWC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" through 1-1/4". Jacket shall be black in color and be radiation-resistant. The outside of the jacket shall have a smooth appearance, Jacket material shall meet guidelines defined in IEEE 323-1974 and IEEE 383-1974. |
|||||||||
Tipo | N/A NWC | |||||||||
Tamaño de campo eléctrico | N/A 3/8 in12 mm | N/A 1/2 in16 mm | N/A 3/4 in21 mm | N/A 1 in27 mm | N/A 1-1/4 in35 mm | |||||
Longitud | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 50 ft15.24 m | |||||
Embalaje | N/A Estándar del Cartón | |||||||||
Diámetro Interior | N/A 0.484 to 0.504 in12.294 to 12.802 mm | N/A 0.622 to 0.642 in15.799 to 16.307 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.041 to 1.066 in26.441 to 27.076 mm | N/A 1.380 to 1.410 in35.052 to 35.814 mm | |||||
Diámetro Exterior | N/A 0.690 to 0.710 in17.526 to 18.034 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.030 to 1.050 in26.162 to 26.670 mm | N/A 1.290 to 1.315 in32.766 to 33.401 mm | N/A 1.630 to 1.660 in41.402 to 42.164 mm | |||||
Aprox. Dentro del Radio de Curvatura | N/A 8.0 in203.2 mm | N/A 9.0 in228.6 mm | N/A 13 in330.2 mm | N/A 15 in381 mm | N/A 18 in457.2 mm | |||||
Peso aprox. por 100 pies | N/A 25 lbs11.34 kg | N/A 29 lbs13.15 kg | N/A 44 lbs19.96 kg | N/A 73 lbs33.11 kg | N/A 100 lbs45.36 kg | |||||
Instalación |
N/A
|
|||||||||
Color | N/A Negro | |||||||||
Aplicación | N/A Aplicación nuclear o la protección radiológica Dónde es Necesario Rango de temperatura MedlinePlus: -40 º F a 192 º F (-40 º C a +89 º C) | |||||||||
Listado | N/A NUCLEAR PROCURMENT ISSUES COMMITTEE (NUPIC) NUPIC number 2651 | |||||||||
Core Material | N/A Galvanized Steel | |||||||||
Ingress Protection (IP) Rating | N/A Ingress Protection (IP) 66/67 | |||||||||
Jacket Material | N/A Polyethylene | |||||||||
Jacket Benefits | N/A Liquid Tight | |||||||||
|